Background and study aims: Hemospray (TC-325) is a mineral powder with adsorptive properties designed for use in various gastrointestinal bleeding (GIB) scenarios. We conducted a systematic review & meta-analysis of randomized controlled trials (RCTs) comparing TC-325 to standard endoscopic therapy (SET) for non-variceal GIB (NVGIB).
Methods: Multiple databases were searched through October 2022. Meta-analysis was performed using a random-effects model to determine pooled relative risk (RR) and proportions with 95 % confidence intervals (CI) for primary hemostasis, hemostasis failure, 30-day rebleeding, length of stay (LOS), and need for rescue interventions. Heterogeneity was assessed using I 2 %.
Results: Five RCTs with 362 patients (TC-325 178, SET 184) - 123 females and 239 males with a mean age 65 ± 16 years). The most common etiologies were peptic ulcer disease (48 %), malignancies (35 %), and others (17 %). Bleeding was characterized as Forrest IA (7 %), IB (73 %), IIA (3 %), and IIB (1 %). SET included epinephrine injection, electrocautery, hemoclips, or a combination. No statistical difference in primary hemostasis between TC-325 compared to SET, RR 1.09 (CI 0.95-1.25; I 2 43), P = 0.2, including patients with oozing/spurting hemorrhage, RR 1.13 (CI 0.98-1.3; I 2 35), P = 0.08. Failure to achieve hemostasis was higher in SET compared to TC-325, RR 0.30 (CI 0.12-0.77, I 2 0), P = 0.01, including patients with oozing/spurting hemorrhage, RR 0.24 (CI 0.09 - 0.63, I 2 0), P = 0.004. We found no difference between the two interventions in terms of rebleeding, RR 1.13 (CI 0.62-2.07, I 2 26), P = 0.8 and LOS, standardized mean difference (SMD) 0.27 (CI, -0.20-0.74; I 2 62), P = 0.3. Finally, pooled rate of rescue interventions (angiography) was statistically higher in SET compared to TC-325, RR 0.68 (CI 0.5-0.94; I 2 0), P = 0.02.
Conclusions: Our analysis shows that for acute NV GIB, including oozing/spurting hemorrhage, TC-325 does not result in higher rates of primary hemostasis compared to SET. However, lower rates of failures were seen with TC-325 than SET. In addition, there was no difference in the two modalities when comparing rates of rebleeding and LOS.
First Page
E288
Last Page
E295
DOI
10.1055/a-2032-4199
Volume
11
Issue
3
Publication Date
3-1-2023
PubMed ID
36968978
Recommended Citation
Deliwala, S. S., Chandan, S., Mohan, B. P., Khan, S., Reddy, N., Ramai, D., Bapaye, J. A., Dahiya, D. S., Kassab, L. L., Facciorusso, A., Chawla, S., & Adler, D. (2023). Hemostatic spray (TC-325) vs. standard endoscopic therapy for non-variceal gastrointestinal bleeding: A meta-analysis of randomized controlled trials. Endoscopy International Open, 11 (3), E288-E295. https://doi.org/10.1055/a-2032-4199