Background: Liver biopsy is the gold standard for histologic diagnosis of parenchymal liver disease. Endoscopic ultrasound-guided liver biopsy (EUS-LB) is increasingly being performed for tissue acquisition. However, the needle size to perform the procedure is still debated. We performed a systematic review and meta-analysis comparing outcomes and safety of two different needles, 19 gauge (G) and 22 G, for EUS-LB.
Methods: A comprehensive search of multiple databases was conducted to identify studies comparing 19 G and 22 G needles for liver biopsy. Studies reporting tissue adequacy, histologic diagnosis, and other relevant outcomes were included. A meta-analysis was conducted using random-effects models, and heterogeneity was assessed using standard methods.
Results: Our analysis of six studies revealed the superiority of 19 G needles in terms of tissue adequacy (odds ratio [OR] 7.9, 95% confidence interval [CI] 1.9-32.0, P = 0.004) and obtaining a histological diagnosis (OR 7.25, 95% CI 1.4-36.7, P = 0.02) compared to 22 G needles. Both needle sizes performed similarly in obtaining long intact core preprocessing; however, 19 G needles yielded significantly longer intact cores postprocessing. Postprocedural pain was similar between groups.
Conclusion: Our meta-analysis supports the preferential use of 19 G needles over 22 G needles for EUS-LB, given their superior performance in tissue adequacy and histological diagnosis with no difference in postprocedural adverse events. These findings underscore the importance of appropriate needle size in optimizing EUS-LB outcomes.
First Page
877
Last Page
883
DOI
10.1080/08998280.2026.2684890
Volume
39
Issue
5
Publication Date
9-1-2026
Medical Subject Headings
Humans; Needles; Liver; Liver Diseases; Endoscopic Ultrasound-Guided Fine Needle Aspiration
PubMed ID
42330162
Recommended Citation
Butt, M. A., Karna, R., Malik, S., Muzammil, T. S., Hammad, S., Mohy-Ud-Din, N., & Bilal, M. (2026). Comparing the diagnostic performance of 19-gauge and 22-gauge needles in endoscopic ultrasound-guided liver biopsy: a systematic review and meta-analysis. Proceedings (Baylor University. Medical Center), 39 (5), 877-883. https://doi.org/10.1080/08998280.2026.2684890