Association of device detected atrial and ventricular tachyarrhythmia with adverse events in patients with an implantable cardioverter-defibrillator
Department
Medicine
Document Type
Article
Publication Title
Journal of Cardiovascular Electrophysiology
Abstract
INTRODUCTION: Heart failure patients with a history of atrial fibrillation (AF) and ventricular tachycardia/ventricular fibrillation (VT/VF) are known to have worse outcomes. However, there are limited data on the temporal relationship between development of these arrhythmias and the risk of subsequent congestive heart failure (CHF) exacerbation and death.
METHODS: The study cohort comprised 5511 patients implanted with an implantable cardioverter-defibrillator (ICD) in landmark clinical trials (MADIT-II, MADIT-RISK, MADIT-CRT, MADIT-RIT, and RAID) who were in sinus rhythm at enrollment. Multivariate cox analysis was performed to evaluate the time-dependent association between development of in-trial device detected AF and VT/VF with subsequent CHF exacerbation and death.
RESULTS: Multivariate analysis showed that AF occurrence and VT/VF occurrence were both associated with a similar magnitude of risk for subsequent CHF exacerbation (HR = 1.73 and 1.87 respectively, p < .001 for both). In contrast, only in-trial VT/VF was associated with a significant > two-fold increase in the risk of subsequent mortality (HR = 2.13, p < .001) whereas AF occurrence was not associated with a significant mortality increase after adjustment for in-trial VT/VF (HR = 1.36, p = .096).
CONCLUSION: Our findings from a large cohort of ICD recipients enrolled in landmark clinical trials show that device detected AF and VT/VF can be used to identify patients with increased risk for CHF exacerbation and mortality. These findings suggest a need for early intervention in CHF patients who develop device-detected atrial and ventricular tachyarrhythmias.
First Page
1203
Last Page
1211
DOI
10.1111/jce.16280
Volume
35
Issue
6
Publication Date
6-1-2024
Publisher
Futura Pub.
Medical Subject Headings
Humans; Defibrillators, Implantable; Male; Female; Tachycardia, Ventricular; Aged; Middle Aged; Atrial Fibrillation; Risk Factors; Heart Failure; Ventricular Fibrillation; Time Factors; Risk Assessment; Electric Countershock; Treatment Outcome
PubMed ID
38606650
Recommended Citation
Abbas, H., Younis, A., Goldenberg, I., McNitt, S., Aktas, M. K., Tabaja, C., & Ojo, A. (2024). Association of device detected atrial and ventricular tachyarrhythmia with adverse events in patients with an implantable cardioverter-defibrillator. Journal of Cardiovascular Electrophysiology, 35 (6), 1203-1211. https://doi.org/10.1111/jce.16280